Dry Mode - During humid conditions, the dry mode automatically reduces the speed of the fans which helps in removing moisture. Fan Mode - While in fan mode, you have three fan speed options to choose from. Cool Mode - You can choose your desired temperature setting from 16 C to 32 C. You can also use the Off timer and sleep mode function under the cool mode operation. Auto Mode - By switching to this mode the air conditioner automatically chooses Heating or Cooling Mode. If the room temperature is less than or equal to 18?C then the air conditioner automatically selects Heating Mode and sets the temperature to 27?C. Similarly, if the room temperature is more than 18?C then the air conditioner automatically selects cooling mode and sets the temperature to 25?C. This mode does not only help in maintaining temperature that ensures human comfort but also saves power.
Condenser Coil
Copper
Copper
Remote Control
Yes
Yes
Technology Used
Coanda Airflow Technology
-
dimensions
Indoor W x H x D
834 mm x 270 mm x 215 mm
-
Outdoor W x H x D
799 mm x 547 mm x 290 mm
-
Outdoor Unit Weight
31 kg
-
Other Dimensions
Indoor Airflow Distance: 10 m, Connection Pipe Gas, Liquid: 9.52, 6.35 mm, Pipe Length Minimum - Maximum: 3 - 20 7.5 m, Maximum Height Difference: 15 m
-
performance features
Panel Display
Yes
Yes
ISEER
4.22 W/W
-
Indoor Noise Level
-
34 dB
power features
Power Consumption
805 W
-
Other Power Features
Running Current: 4.3 A, Standard Cooling at 100% Capacity Minimum - Maximum Operating Range: 900 - 4100 W, Standard Cooling at 50% Capacity: 1700 W, Power Consumption at 50% Capacity: 320 W, Rated ISSER: 5.12 kWh, Electricity Consumption Per Annum: 514 kWh